• Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy

Forum rules:Click here to view the forum rules

  1. Topic title should contain: the device's manufacturer, full model and the brief description of problem.
  2. Topic message should contain: the PCB marking code (required in case of hardware repairs), an extended description of problem, things you have checked/replaced/measured, your conclusions and the question. If you are not able to find the PCB marking code, please read THIS TOPIC. If you still cannot locate the PCB markings, please upload a clean, both-side photos of the mainboard - it is required to remove any films, modules or brackets possibly covering these markings.
  3. Before posting a new topic please read all topics in TRAININGS subforum and make a preliminary diagnostic based on the content of those trainings.
  4. Uploading of any complete schematics, BIOS / firmware files or any other kind of documentation, or linking to 3rd party websites with such files, is STRICTLY PROHIBITED. You can only upload the small portion of documentation or, link to BIOS file on UNVERIFIED BIOS FILES subforum, which simplifies the diagnostics/repair. You are not allowed to upload more then one complete page of instruction/schematic per single topic. The file you upload must not contain any watermarks, "confidential" markings, links or email addresses and cannot be password-protected.
  5. It is only permitted to describe one faulty device per single topic - you should always open a new topic for each subsequent device.
  6. Requesting of the full schematics, BoardView files, BIOS files or any other kind of documentation is NOT ALLOWED in this subforum. If you need to ask for any of these, you should open a new topic in DOCUMENTATION/BIOS REQUEST subforum.

#1Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Vogelek23 6 September 2025, 14:08
Koledzy, potrzebuję Waszej pomocy!

Na stole tytułowy wzmacniacz stereo. Uszkodzona przetwornica +8V_STANDBY na układzie IC2601 - LNK562PN. Temat niby prosty, ale po wymianie rezystora R2601 (spalony - szeregowy rezystor 8,2Ω podający napięcie 320V na pin 5 układu IC2601 poprzez uzwojenie pierwotne transformatora) oraz samego IC2601 brak napięcia stand-by 8V.

Sprawdziłem przejścia - transformator wygląda na sprawny, wszystkie uzwojenia pokazują bardzo małe rezystancje. Znalazłem uszkodzoną diodę D2603 od napięcia pomocniczego (VBIAS) oraz kondensator elektrolityczny za diodą (zwarty), zostały wymienione. Układ IC2601 nie startuje w ogóle, pomimo, że napięcie zasilania jest poprawne. Rezystor R2601 wymieniłem na 4x 33Ω/0.25W połączone równolegle (nie miałem 8,2Ω/1W), co daje wypadkową rezystancję 8,25Ω więc powinno być w porządku. Sprawdziłem wszystkie półprzewodniki, rezystory i kondensatory w okolicy tej przetwornicy - wszystkie wydają się być sprawne. Poniżej kilka zdjęć płytki.

Proszę Was o pomoc w uruchomieniu tej przetwornicy. Przewiduję nagrodę dla osoby, która przyczyni się do skutecznej naprawy: 100 Punktów, z możliwością zamiany na gotówkę (PayPal).

Image
Image
Image
Image
Image
Image

Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Google Adsense [BOT] 6 September 2025, 14:08

#2 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by matic 7 September 2025, 15:34
Hello!

Measure the voltages to ground on pins 3, 4, 5 of the LNK chip.

#3 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by klarus 8 September 2025, 12:11
Lukasz,

R2608 co idzie do transoptora jest spalony czy tylko brudny? Pozdrawiam

#4 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Vogelek23 8 September 2025, 12:34
Dziękuję Kolegom za podjęcie tematu.

matic wrote:Measure the voltages to ground on pins 3, 4, 5 of the LNK chip.
3 - 5,8V
4 - 0V,
5 - 335V.
All measured directly on the chip pins (top side) in reference to "hot" ground. There was a burnt flux residue on pin 5 visible on the photo, which looks like cold solder, but this has been cleaned and checked and no cold solder is here for sure.

klarus wrote:R2608 (...) jest spalony czy tylko brudny?
Tylko brudny po przelutowaniu, już wyczyściłem cały flux z tego obszaru. R2608 ma wartość 10kΩ, a R2609 ma wartość 1kΩ (zmierzone).

Transoptor nie bierze udziału w "produkowaniu" napięcia +8V_STANDBY - ten element jest częścią przetwornicy głównej, zasilającej wzmacniacze. LNK562PN jest "samodzielnym" sterownikiem przetwornicy +8V_STANDBY. Sprawdziłem wyjście tej przetwornicy i zwarcia nie ma - podałem w tę gałąź 8V i pobór prądu wynosi 10mA. Obawiam się, czy po uszkodzeniu IC2601 nie doszło do zwarcia lub przebicia między zwojami w uzwojeniu pierwotnym transformatora STANDBY, ale nie mam jak tego wykluczyć na ten moment.

#5 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by matic 8 September 2025, 12:52
Measure the resistance to ground on pin 4 of the LNK chip.

#6 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Vogelek23 8 September 2025, 13:15
It is exactly 2,98kΩ with R2606 assembled (3kΩ shunt) and 1MΩ -> 750kΩ dropping slowly with R2606 removed.

#7 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy  [SOLVED]


by matic 8 September 2025, 15:34
Remove the LNK chip from the board and build a simple circuit (picture below) to make sure the chip is functional.
Use an oscilloscope to check if you get pulses on pin 5.
Image

#8 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Vogelek23 8 September 2025, 16:53
Both chips give ~32kHz square wave at around 10VP-P.

#9 Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Vogelek23 8 September 2025, 18:08
Problem rozwiązany!

Wymieniłem transformator T2601 na inny, wyciągnięty ze starej ładowarki LG STA-U14UD. Nie obeszło się bez kombinowania z obudową transformatora (musiałem ją trochę przyciąć od strony uzwojenia wtórnego) oraz wyginaniem pinów, aby transformator był solidnie przylutowany. Napięcie +8V_STANDBY wróciło. Przeczucie o uszkodzeniu transformatora było trafne - najprawdopodobniej doszło do zwarć międzyzwojowych uzwojenia pierwotnego lub pomocniczego i sterownik IC2601 nie mógł się wzbudzić.

Wszystkim, którzy podjęli temat - a w szczególności koledze matic za obwód testowy sterownika - serdecznie dziękuję! Załączam zdjęcie modyfikacji.
Image

Re: Marshall Hanwell 50-th Anniversary Edition ALC0100-2300-C - martwy


by Google Adsense [BOT] 8 September 2025, 18:08

Who is online

Users browsing this forum: No registered users and 0 guests

_______________________________
All rights reserved. Unauthorised copying of this website's content or any of its part is strictly forbidden.
Any trademarks, brand names, products or services published on this website belong to their legal owners, are copyrighted and used for information purposes only.
cron