matic написав:pawel1978 написав:I'm not sure where to check the forward and reverse voltage..Forward voltage = Red probe of multimeter to the anode pin of diode and black probe to the cathode pin of diode.
Reverse voltage = Red probe of multimeter to the cathode pin of diode and black probe to the anode pin of diode.
So you already did it.pawel1978 написав:PD1202 - multimeter measurement in diode mode - no conduction in one directionSo the reverse voltage is out of range of multimeter.pawel1978 написав:reading 253 in the other direction.That's the forward voltage, which means 0.253Vpawel1978 написав:pads under PQ 1203Are these measurements correct?
1-19,5V
4-19,5V
8-19,5V
If the voltage on pad 8 is 19.5V, I expect the voltage 19.247V on pad 1 on the place of these transistor.
So I did the pad measurements again under pq1203.
no pd1202 diode
1-0V
4-0V
8-19.8V
with diode d1203
1-19.5V
4-19.5V
8-19.8V