• TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL

Pravila foruma:Klikni tukaj za prikaz pravil na forumu

  1. Naslov teme mora vsebovati: proizvajalca naprave, poln model in kratek opis okvare.
  2. Sporočilo teme mora vsebovati: oznako tiskanega vezja (v primeru popravil strojne opreme), razširjen opis okvare, kaj je bilo preverjeno, zamenjano in/ali izmerjeno, sklep in vprašanje. Če ne morete najti oznake tiskanega vezja, morate prebrati TO TEMO. Če še vedno ne najdete oznake, prosim objavite kakovostne fotografije obeh strani matične plošče - potrebno je odstraniti vse folije in module, ki bi lahko zakrivali te oznake.
  3. Pred objavo nove teme, preberite vse teme v podforumu USPOSABLJANJA, in naredite predhodno diagnostiko na podlagi vsebine teh usposabljanj.
  4. Nalaganje celotnih navodil/shem, BIOS / firmware datotek, ali objavljanje povezav, ki vodijo do drugih spletnih strani s takšnimi datotekami, je SROGO PREPOVEDANO. Lahko objavite le majhen del navodil/shem, ali povezavo na BIOS datoteko v podforumu NEVERIFICIRANE DATOTEKE BIOS/EFI. V eni temi ne smete objaviti več kot eno stran navodil/shem. Datoteka ne sme vsebovati vidnih žigov "zaupno",, e-poštnih naslovov ipd.
  5. V eni temi lahko opišete SAMO eno napravo. Za vsako drugo okvarjeno napravo morate odpreti novo temo.
  6. Zahteve za sheme, boardview, fotografije matičnih plošč, datoteke BIOS-a ali servisne priročnike za storitve NISO DOVOLJENE. Če želite vprašati za katero koli od teh, odprite novo temo v podforumu ZAHTEVA ZA DOKUMENTACIJO & DATOTEKO BIOS/EFI.
Ta tema je označena kot ARHIVSKA. Odgovorite samo, če vaše sporočilo vsebuje rešitev (Pravila in Pogoji, 12.1).

#1 TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 5 Oktober 2017, 16:52
Witam wszystkich bardzo serdecznie

Mam przypadek uszkodzenia braku zasilania podświetlenia świetlówek CCFL na wyjściach brak napięcia. Czasami uda się ze układ zaskoczy i podświetlenie uruchomi się i napięcia zaskoczą w dole układu zasilania. Telewizor działa prawidłowo dźwięk i obraz generują się menu sprawne brak tylko podświetlenia.

Sprawdzone pod kątem zimnych lutów, pobieliłem większość układów problem nie ustąpił....
Kondensatory wyglądają na OK żadne nie wybrzuszone od góry i dołu (nie mam miernika do pomiarów ESR kondensatorów).
Brak zwarcia przemierzyłem wszystkie diody bezpieczniki itd...

Bardzo proszę o pomoc nie mam doświadczenia z telewizorami. Gdzie szukać przyczyny od czego zacząć co przemierzyć

Wstępnie pomierzyłem napięcia wejściowe góra wydaje się być ok ale na dole brak napięcia

Przesyłam zdjęcia płyty zasilającej :

PRZÓD
Slika

TYŁ:
Slika


I jeszcze zdjęcia z bliska :
Slika

Slika

Slika

Slika

Slika

Pozdrawiam i dziękuję za odpowiedź

Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a Google Adsense [BOT] 5 Oktober 2017, 16:52

#2 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a matic 12 Oktober 2017, 11:59
Hello!

Measure voltage on highlighted capacitors, when the TV is turned ON.

Slika

#3 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 14 Oktober 2017, 22:00
matic napisal/-a:ello!

Measure voltage on highlighted capacitors, when the TV is turned ON.


All capacitors 0V

Nie ma napięcia na tych kondensatorach

:(

#4 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a matic 15 Oktober 2017, 12:49
325V present on primary main filter capacitor?

Don't forget to discharge this capacitor before touching primary components!

#5 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 15 Oktober 2017, 21:13
matic napisal/-a:325V present on primary main filter capacitor?

Don't forget to discharge this capacitor before touching primary components!



On this capacitor stable 231 V

#6 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a matic 16 Oktober 2017, 16:58
hukolo napisal/-a:On this capacitor stable 231 V
Only 231V? I think it should be around 300V.

If voltage on is only 231V, measure AC voltage on thermistor marked on the following picture.

Slika

#7 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 17 Oktober 2017, 08:43
matic napisal/-a:
hukolo napisal/-a:On this capacitor stable 231 V
Only 231V? I think it should be around 300V.

If voltage on is only 231V, measure AC voltage on thermistor marked on the following picture.

Slika



I'm sorry my mistake

The big capacitor is DC - 320 V ! - stable

On the varistor AC - 121 V - stable

Hmmm I think the tension on these elements are OK,
What do you think matic

#8 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a matic 17 Oktober 2017, 22:04
hukolo napisal/-a:The big capacitor is DC - 320 V ! - stable
It is correct value.

hukolo napisal/-a:On the varistor AC - 121 V - stable
The highlighted component is thermistor, not varistor.
121 V AC on thermistor -> impossible (probably wrong measurenent)
Correct value should be around 0.5Vac to 10Vac, if the power supply does not start.

If you still don't get the correct voltage on this component, measure resistance directly on this component (no need to remove it from the board). Of course with disconnected power supply, and discharged big capacitor.
I expect that it is no problem with this thermistor, because it is correct voltage value on the big capacitor.

#9 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a Usunięty Użytkownik 402 18 Oktober 2017, 19:43
Zawsze wymienia się drobne elektrolity w przetwornicy, potem patrzy co dalej. Pamiętaj żeby było one dobrej jakości i na 105 stopni.

#10 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 19 Oktober 2017, 11:41
LAZY napisal/-a:Zawsze wymienia się drobne elektrolity w przetwornicy, potem patrzy co dalej. Pamiętaj żeby było one dobrej jakości i na 105 stopni.


Wymieniłem wszystkie elektrolity na płycie i sytuacja nadal taka sama.


I measure resistance directly on this thermistor = 12 ohm


ps. raz udało się wystartować płycie podświetlenie było lecz po ponownym wyłączeniu i włączeniu brak podświetlenia

#11 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a Sokon 19 Oktober 2017, 21:35
Zacznijmy od tego, że szukasz usterki w złym miejscu... Zasilacz masz sprawny a uszkodzenie jest w sekcji inwertera podświetlenia i to tam musisz szukać.
Na 99% OVP lub OCP blokuje driver inwertera...

#12 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 19 Oktober 2017, 23:09
Sokon napisal/-a:Zacznijmy od tego, że szukasz usterki w złym miejscu... Zasilacz masz sprawny a uszkodzenie jest w sekcji inwertera podświetlenia i to tam musisz szukać.
Na 99% OVP lub OCP blokuje driver inwertera...



Sokon a możesz mnie nakierować gdzie szukać sekcji OVP i OCP jest możliwość abyś zaznaczył na zdjęciu bardzo będę wdzięczny szukałem schematu do tego tv ale nic nie mogłem znaleźć.

#13 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a Sokon 19 Oktober 2017, 23:36
Driver to ten 28 nóżkowy scalak. Poszukaj jego datasheet i sprawdź kiedy się zabezpiecza....

#14 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a hukolo 21 Oktober 2017, 13:36
Sokon napisal/-a:Driver to ten 28 nóżkowy scalak. Poszukaj jego datasheet i sprawdź kiedy się zabezpiecza....


Ten scalak to BD9766FV

tu jest link do schematu

https://www.promelec.ru/pdf/BD9766FV.pdf

Jest możliwość sprawdzenia tego układu poprzez pomiar napięć na jego nogach ?

#15 Re: TV Toshiba LCD: 37AV501P - Brak zasialania podświetlenia CCFL


Napisal/-a Sokon 22 Oktober 2017, 09:34
Zadajesz pytanie jakbyś liczył na to, że ktoś za Ciebie naprawi ten TV...
Masz datasheet układu - szukasz na których nogach układu jest zasilanie, gdzie jest zabezpieczenie nadprądowe i nadnapięciowe (w tym przypadku są 2 kanały), gdzie jest sterowanie mosfetami przetwornicy i mierzysz wszystko po kolei. W datasheet masz tabelkę z prawidłowymi wartościami, a w przypadku zabezpieczeń wartościami maksymalnymi. Pomocny byłby oscyloskop.

I pamiętaj - naprawa przetwornic impulsowych i inwerterów to nie zabawa - tu są naprawdę wysokie napięcia !

Ta tema je označena kot ARHIVSKA. Odgovorite samo, če vaše sporočilo vsebuje rešitev (Pravila in Pogoji, 12.1).

Kdo je na strani

Po forumu brska: 0 registriranih uporabnikov in 0 gostov

_______________________________
Vse pravice pridržane. Nepooblaščeno kopiranje vsebine te spletne strani ali njenega dela je strogo prepovedano.
Vse blagovne znamke, izdelki ali storitve, objavljene na tej spletni strani, pripadajo njihovim zakonitim lastnikom, so avtorsko zaščitene in se uporabljajo samo v informativne namene.