#1 Jovy Re-7500 i profile


by greg1987gt 11 December 2010, 12:04
Witam . Chciałbym w tym temacie rozwiac swoje wątpliwości .
Dolna grzałka ma 3 tryby pracy , ponieważ stację mam od niedawna :
- podgrzewanie wstępne - 400C w 3 minuty
- wygrzewanie - 500C w 4 minuty
- szybkie wygrzewanie - 750C w 5 minut

Górna grzałka ma 2 tryby pracy :
- wygrzewanie - 600C w 50 sekund
- szybkie wygrzewanie - 800C w 1 minute

Czy ktoś orientuje sie jakiej opcji uzyc na jakim układzie itp . Poniewaz już się pogubiłem kiedy uzyc podgrzewania a kiedy wygrzewania czy tez szybkiego wygrzewania .




Ma może ktoś gotowe profile do tej stacji ??

Re: Jovy Re-7500 i profile


by Google Adsense [BOT] 11 December 2010, 12:04

#2 Re: Jovy Re-7500 i profile  [SOLVED]


by maxim21 11 December 2010, 17:24
Dear Sir !
you MUST put termosensor on motherboard !
only temp of motherboard is only true information!
temp of heaters is not good for the construction of reflow chart

1st phase - preheat - 150°C for 2 minutes
2nd phase - soak - 180°С - activating flux for 30-40 seconds
3rd phase - reflow - 240°С (lead free) or 210°С (lead) for 20-25 seconds max!
4th phase - cooling - for as long as the temperature drops below 50°C

Image

#3 Re: Jovy Re-7500 i profile


by AdamStar 11 December 2010, 19:58
Na początek polecam Ci pobranie profili ze strony Jovy i przetestowanie ich. Najważniejsze w tej stacji jest odpowiednie wyprofilowanie termopary, tak aby pomiar temperatury PCB był jak najbardziej zbliżony do wartości rzeczywistej (jest to opisane w instrukcji).

#4 Re: Jovy Re-7500 i profile


by greg1987gt 13 December 2010, 00:55
Dzięki za pomoc

Re: Jovy Re-7500 i profile


by Google Adsense [BOT] 13 December 2010, 00:55

Who is online

Users browsing this forum: No registered users and 1 guest

_______________________________
All rights reserved. Unauthorised copying of this website's content or any of its part is strictly forbidden.