After replacing PR57 ACDET is 2,72V. Thank You. It could damage ACDET input? Absolute max for ACDET is 7V.
Current is about 100mA.
PL10 9,02V
PL4 0V
no voltage on other coils.
Remeasured voltages:
1 ACN- 20,1V
3 CMSRC- 20,1V
4 ACDRV- 26V
5 ACOK - 0,18V
6 ACDET - 2,72V
15 BATPRES- 0V
17 BAT- 7,1V
18 BATDRV - 9V
20 SRP - 9V
24 REGN - 5,38V
25 BTST - 14,3v
28 VCC - 19.78V
Is it damaged PU3? What could I check to be sure?
Current is about 100mA.
PL10 9,02V
PL4 0V
no voltage on other coils.
Remeasured voltages:
1 ACN- 20,1V
3 CMSRC- 20,1V
4 ACDRV- 26V
5 ACOK - 0,18V
6 ACDET - 2,72V
15 BATPRES- 0V
17 BAT- 7,1V
18 BATDRV - 9V
20 SRP - 9V
24 REGN - 5,38V
25 BTST - 14,3v
28 VCC - 19.78V
Is it damaged PU3? What could I check to be sure?